Email:meditech@cn-meditech.com | Whatsapp:+86 13276687134

Cn-Meditech  |  SKU: CNME0112H2

Portable ECG Dynamic Electrocardiogram 24 Hours ECG System Holter ECG

$546.00

Our Advantages:

-Extensive Product Range
One-stop supply from consumables to advanced medical equipment.

-Customizable Solutions
OEM/ODM, packaging, and product bundles to fit client demands.

-Price Match Guarantee
We are committed to offering our customers the most competitive pricing.

-Reliable After-Sales Service
Prompt support for setup, use, and training.

Shipping costs may fluctuate due to various factors. If you find the quoted rate unusually high, please feel free to contact us for confirmation.

SHIPPING

Air shipping ≤20 kg

Sea shipping> 20 kg

If shipped by air delivery will take approximately 10 to 20 days. lf shipped by sea, it may take 10 to 45 days.

For detailed information, please refer to our Shipping Policy or contact us at meditech@cn-meditech.com.

SHIPPING REGIONS

As long as you can place an order, we can ship the goods to your country.

100% PAYMENT SECURE

We ensure secure payment with PEV

Model:CNME0112H2

Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Function:

*Adopt 12-lead system of international standard, continuously record ECG waveform for 24-hour.
*Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
*With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
*Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
*All pacemakers(such as AAI, WI, DDD etc.,) can be analyzed by the powerful pacemaker analysis function.
*Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
*With analysis functions for 5-minute, 1-hour and whole heart rate variability.
*One-key print, convenient and fast to print the reports.
*The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
*“T-Wave alternation" is an important index to predict the malignant arrhythmia and sudden cardiac death.
*With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.


Performance:

*Lead: standard 12-lead
*Power supply: one“AAA”alkaline battery
*Interface: USB2.0
*Input impedance:≥10MQ
*CMR:≥60dB
*Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%
*Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.
*System noise:≤50μVp-p
*Multichannel crosstalk:≤0.2mV
*Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.
*Minimum measure signal: 50 μV
*Timing accuracy: the overall error during 24h shall not exceed 30s.


Physical characteristic:

*Recorder dimension: 81mm(L) X 60mm(W) X 22mm(H)
*Weight: about 61.5g(without batteries)


Accessories:

*Lead cable (1 set)
*ECG electrode (1 bag)
*USB cable(1)
*Software(1)
*Bag(1)
*User manual(1)

Frequently Asked Questions

What certificates do you have?

All our products come with the necessary certifications, including CE and ISO, with some items also FDA-approved. 

Certification details are clearly indicated for each product. 

Please ensure your purchase complies with the regulations of your country. We deliver to the designated location, while responsibility for local compliance remains with the buyer.

How long does it take to ship?

We will basically ship your order within three working days of receiving the order information, most of the equipment need to change the power supply voltage and plug according to the destination country.

What is the installation, training and after-sales service for the products?

We will send the product manual with the goods, or the operation video disc, or later send the operation video, at the same time, our engineers can also be online training, most of the products can be free of charge to guide the repair and replacement of spare parts within one year of non-human damage. We also have co-operative engineers in some countries, they can help to deal with the above matters.

Is there a warranty on the healthcare equipment you sell?

Yes, of course.

1-Year Limited Warranty:

We guarantee our products against defects in materials and workmanship for a period of one year from the date of purchase.Should your product exhibit any issues during this time due to manufacturing faults, we will provide free replacement parts to rectify the problem.

 Lifetime Cooperation:

Beyond the initial warranty period, we offer lifetime cooperation to assist you with any technical difficulties you may encounter.Our team of experienced engineers is available online to diagnose issues and provide guidance for repair, ensuring your product continues to perform optimally for years to come.

 Terms and Conditions Apply:

The warranty covers non-human damage only.

Proof of purchase may be required to validate warranty claims.

Exclusions may apply, refer to our full terms and conditions for details.

Do you offer technical support for the healthcare equipment you sell?

We offer lifetime cooperation to assist you with any technical difficulties you may encounter.  Our team of experienced engineers is available online to diagnose issues and provide guidance for repair, ensuring your product continues to perform optimally for years to come.

Can I return or exchange healthcare equipment if it doesn't meet my needs?

No, we cannot.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Cn-Meditech

Portable ECG Dynamic Electrocardiogram 24 Hours ECG System Holter ECG

$546.00

Model:CNME0112H2

Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Function:

*Adopt 12-lead system of international standard, continuously record ECG waveform for 24-hour.
*Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
*With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
*Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
*All pacemakers(such as AAI, WI, DDD etc.,) can be analyzed by the powerful pacemaker analysis function.
*Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
*With analysis functions for 5-minute, 1-hour and whole heart rate variability.
*One-key print, convenient and fast to print the reports.
*The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
*“T-Wave alternation" is an important index to predict the malignant arrhythmia and sudden cardiac death.
*With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.


Performance:

*Lead: standard 12-lead
*Power supply: one“AAA”alkaline battery
*Interface: USB2.0
*Input impedance:≥10MQ
*CMR:≥60dB
*Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%
*Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.
*System noise:≤50μVp-p
*Multichannel crosstalk:≤0.2mV
*Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.
*Minimum measure signal: 50 μV
*Timing accuracy: the overall error during 24h shall not exceed 30s.


Physical characteristic:

*Recorder dimension: 81mm(L) X 60mm(W) X 22mm(H)
*Weight: about 61.5g(without batteries)


Accessories:

*Lead cable (1 set)
*ECG electrode (1 bag)
*USB cable(1)
*Software(1)
*Bag(1)
*User manual(1)

View product