Free domestic shipping

Gynecological Surgery Leep Machine Electrosurgical Generator Loop Electrosurgical Excision Procedure

$1,200.00
Applicable To:
obstetrics and gynecology (cutting,hemostasis,cauliflower, cervical erosion,LEEP,all kinds of laparoscopic operations with laparoscopy,various gynecologic operations)
Documents

SHIPPING

Shipping process time is 3-5 days.

SHIPPING REGIONS

As long as you can place an order, we can ship the goods to your country.

100% PAYMENT SECURE

We ensure secure payment with PEV

Model:CNME011112B-leep

Electrosurgical unit parameter:

Max output power:monopolar:200W,bipolar:70W
Working frequency:360-460kHz
5 working modes:①Pure cut,②Blend cut,③Soft Coag,④Strong Coag: 80W,⑤Bipolar Coag
Power supply:AC110 or 220V,50/60Hz

Smoking device parameter:

Maximum flow:0-200L/min(adjustable suction force)
Absorption efficiency:>95%
Noise level:maximum 40dB

LEEP operation superiority:

1.The use of LEEP for gynecologic uterine lesions has improved the accuracy, controllability and safety of the operation.
2.It can be applied to the treatment of various diseases in obstetrics and gynecology (cutting,hemostasis, cauliflower, cervical erosion, LEEP, all kinds of laparoscopic operations with laparoscopy, various gynecologic operations) simplifying the procedure,reducing the cost of the operation and improving the safety of the operation.
3.Many kinds of knife heads are suitable for cervical conization and vulva management, no carbonization and no pathological changes.
4.Spherical electrodes can be used for hemostasis, not focus blood vessels, do not damage nearby tissues, and recover faster after operation.
5.Needle shaped electrodes can be used for fine cutting.
6.Different thickness electrodes have different hemostatic effects.

BEST ELECTROSURGICAL

A table comparing the facets of 5 products
Facet
Model
CNME011112A-leep
CNME011105
CNME011117
CNME011118V
CNME0111V1
Maximum power
Monopolar:200W Bipolar:50W
Monopolar:100W Bipolar:50W
Monopolar:400W Bipolar:70W
Monopolar:100W Bipolar:60W
Monopolar:200W Bipolar:50W
Applicable surgeries
Gynecological Surgery
Dermatology, Dentistry, Plastic surgery
General surgery, Endoscopic surgery,Thoracic surgery, Orthopedics, Obstetrics and gynecology, Urologic surgery, Cerebral surgery,Microsurgery, ENT surgery and etc.
Dermatology, Dentistry, Plastic surgery,pet open surgery
Pet open surgery
Working mode
①Pure cut,②Blend cut 1,③Blend cut 2,④Soft Coag,⑤Strong Coag,⑥Bipolar Coag
①Pure cut,②Blend cut,③Contact Coag,④Bipolar Coag
①Pure cut,②Blend cut 1,③Blend cut 2,④Blend cut 3,⑤Spray Coag,⑥Forced Coag,⑦Contact Coag,⑧Standard Bipolar Coag,⑨Auto Bipolar Coag
①Pure Cut,②Blend Cut 1,③Blend Cut 2,④Spray Coag,⑤Forced Coag,⑥Bipolar Coag
①Pure cut,②Blend cut,③Soft Coag,④Strong Coag,⑤Bipolar Coag
Advantages
The smoker is designed independently and can be used with other electrosurgical units
FDA Certification
Two pencils work simultaneously,Memory records features.
Also suitable for pets,High cost performance
Standard with pet special conductive bar
View more View more View more View more View more

Frequently Asked Questions

What certificates do you have?

CE, ISO at least, some of the products have FDA, we will send copies of relevant documents with the shipment according to the customs clearance requirements or market policies of each country.

How long does it take to ship?

We will basically ship your order within three working days of receiving the order information, most of the equipment need to change the power supply voltage and plug according to the destination country.

What is the installation, training and after-sales service for the products?

We will send the product manual with the goods, or the operation video disc, or later send the operation video, at the same time, our engineers can also be online training, most of the products can be free of charge to guide the repair and replacement of spare parts within one year of non-human damage. We also have co-operative engineers in some countries, they can help to deal with the above matters.

Is there a warranty on the healthcare equipment you sell?

Yes, of course.

1-Year Limited Warranty:

We guarantee our products against defects in materials and workmanship for a period of one year from the date of purchase.Should your product exhibit any issues during this time due to manufacturing faults, we will provide free replacement parts to rectify the problem.

 Lifetime Cooperation:

Beyond the initial warranty period, we offer lifetime cooperation to assist you with any technical difficulties you may encounter.Our team of experienced engineers is available online to diagnose issues and provide guidance for repair, ensuring your product continues to perform optimally for years to come.

 Terms and Conditions Apply:

The warranty covers non-human damage only.

Proof of purchase may be required to validate warranty claims.

Exclusions may apply, refer to our full terms and conditions for details.

Do you offer technical support for the healthcare equipment you sell?

We offer lifetime cooperation to assist you with any technical difficulties you may encounter.  Our team of experienced engineers is available online to diagnose issues and provide guidance for repair, ensuring your product continues to perform optimally for years to come.

Can I return or exchange healthcare equipment if it doesn't meet my needs?

No, we cannot.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
A table comparing the facets of 5 products
Facet
View more View more View more View more View more
Cn-Meditech

Gynecological Surgery Leep Machine Electrosurgical Generator Loop Electrosurgical Excision Procedure

$1,200.00

Model:CNME011112B-leep

Electrosurgical unit parameter:

Max output power:monopolar:200W,bipolar:70W
Working frequency:360-460kHz
5 working modes:①Pure cut,②Blend cut,③Soft Coag,④Strong Coag: 80W,⑤Bipolar Coag
Power supply:AC110 or 220V,50/60Hz

Smoking device parameter:

Maximum flow:0-200L/min(adjustable suction force)
Absorption efficiency:>95%
Noise level:maximum 40dB

LEEP operation superiority:

1.The use of LEEP for gynecologic uterine lesions has improved the accuracy, controllability and safety of the operation.
2.It can be applied to the treatment of various diseases in obstetrics and gynecology (cutting,hemostasis, cauliflower, cervical erosion, LEEP, all kinds of laparoscopic operations with laparoscopy, various gynecologic operations) simplifying the procedure,reducing the cost of the operation and improving the safety of the operation.
3.Many kinds of knife heads are suitable for cervical conization and vulva management, no carbonization and no pathological changes.
4.Spherical electrodes can be used for hemostasis, not focus blood vessels, do not damage nearby tissues, and recover faster after operation.
5.Needle shaped electrodes can be used for fine cutting.
6.Different thickness electrodes have different hemostatic effects.

Documents

  • Invoice,Packing list and Copy of ISO13485 with goods
  • All documents sent by email
View product