Email:meditech@cn-meditech.com | Whatsapp:+86 13611512069

Cn-Meditech

High Frequency Electrosurgical Unit Monopolar Bipolar Electrocautery Machine

$1,163.00
Applicable To:
General Surgery, Gynecology, Plastic Surgery, Dermatology, Veterinary Surgery and other routine surgical procedures for tissue cutting, dissection and hemostasis.

Our Advantages:

-Extensive Product Range
One-stop supply from consumables to advanced medical equipment.

-Customizable Solutions
OEM/ODM, packaging, and product bundles to fit client demands.

-Price Match Guarantee
We are committed to offering our customers the most competitive pricing.

-Reliable After-Sales Service
Prompt support for setup, use, and training.

Shipping costs may fluctuate due to various factors. If you find the quoted rate unusually high, please feel free to contact us for confirmation.

SHIPPING

Air shipping ≤20 kg

Sea shipping> 20 kg

If shipped by air delivery will take approximately 10 to 20 days. lf shipped by sea, it may take 10 to 45 days.

For detailed information, please refer to our Shipping Policy or contact us at meditech@cn-meditech.com.

SHIPPING REGIONS

As long as you can place an order, we can ship the goods to your country.

100% PAYMENT SECURE

We ensure secure payment with PEV

Model:CNME011117C

This electrosurgical unit delivers stable power output with low tissue thermal injury. Supporting hand/foot control and independent power adjustment, it is widely used in general surgery, gynecology, plastic surgery and veterinary operations for cutting, dissection and hemostasis.

Features:

The 416KHz (± 10%) high frequency current generated by this machine can perform
surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut, ; Monopolar coagulation: spray coagulation, soft
coagulation and standard bipolar six working modes.

*Full-function automatic power compensation.
*The high-frequency generator has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope, laparoscope and other endoscopes. 
*Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate. 
*Patient circuit bipolar electrode plate contact quality detection system. 
*Monopolar output can be controlled either by hand or foot, and monopolar/bipolar automatic output. 
*This machine has a power-off protection circuit, which can memorize the output set value of each function in real time. 
*Remote fault diagnosis. 
*Human voice alarm function
*Passed EMC test.

Rated output power:

*Pure cut:1w~350w(Max.400W,load 500 Ω);
A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasis. (No-focus precision cutting, 100% cutting.)

*Blend cut 1: 1W~250W(load 500 Ω);
Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.(Superficial focal gamma accurate cutting 80% cutting, 20% coagulation.)

*ENDU Cut: 99% (load 500 Ω);
The mode is used to automatically controlled cut system to reduce the complication rate of endoscopic sphincterotomy (EsT) and serum hyperamylasemia after EST compared to the conventional blended cut mode.

*Spray coagulation: 1W~80W(load 500 Ω);
Spray output is made for direct coagulation at the tissue with spark. Above spark does not give any cutting effect as its CREST FACTOR is high. (Massive coagulation)

*Desicate coagulation: 1W~120W(load 500 Ω);
Coagulation in which the active electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries it ensures pinpoint desiccation with less destruction of peripheral tissue.

*Standard bipolar coagulation: 1w~70w(load 100 Ω);
Bl-COAG- For highly precise control over coagulation process and privations of carbonization.

*Power consumption of the whole machine: ≤ 1100vA.(cut function 350W);

Normal operation:

*Ambient temperature range: 5℃~40℃;
*Relative humidity range: ≤ 80%;
*Atmospheric pressure range: 86.0~106.0kPa;
*Power supply: 220V±10%,50±1Hz; or110V±10%,60±1Hz
 *Working frequency: 416kHz;

Transportation and storage:

*Ambient temperature range:-40℃~55℃;
*Relative humidity range: ≤ 95%;
*Atmospheric pressure range: 50.0~106.0kPa.

A table comparing the facets of 5 products
Facet
View more View more View more View more View more

Frequently Asked Questions

What certificates do you have?

All our products come with the necessary certifications, including CE and ISO, with some items also FDA-approved. 

Certification details are clearly indicated for each product. 

Please ensure your purchase complies with the regulations of your country. We deliver to the designated location, while responsibility for local compliance remains with the buyer.

How long does it take to ship?

We will basically ship your order within three working days of receiving the order information, most of the equipment need to change the power supply voltage and plug according to the destination country.

Air shipping ≤20 kg

Sea shipping> 20 kg

If shipped by air delivery will take approximately 10 to 20 days. lf shipped by sea, it may take 10 to 45 days.

What is the installation, training and after-sales service for the products?

We will send the product manual with the goods, or the operation video disc, or later send the operation video, at the same time, our engineers can also be online training, most of the products can be free of charge to guide the repair and replacement of spare parts within one year of non-human damage. We also have co-operative engineers in some countries, they can help to deal with the above matters.

Is there a warranty on the healthcare equipment you sell?

Yes, of course.

1-Year Limited Warranty:

We guarantee our products against defects in materials and workmanship for a period of one year from the date of purchase.Should your product exhibit any issues during this time due to manufacturing faults, we will provide free replacement parts to rectify the problem.

 Lifetime Cooperation:

Beyond the initial warranty period, we offer lifetime cooperation to assist you with any technical difficulties you may encounter.Our team of experienced engineers is available online to diagnose issues and provide guidance for repair, ensuring your product continues to perform optimally for years to come.

 Terms and Conditions Apply:

The warranty covers non-human damage only.

Proof of purchase may be required to validate warranty claims.

Exclusions may apply, refer to our full terms and conditions for details.

Do you offer technical support for the healthcare equipment you sell?

We offer lifetime cooperation to assist you with any technical difficulties you may encounter.  Our team of experienced engineers is available online to diagnose issues and provide guidance for repair, ensuring your product continues to perform optimally for years to come.

Can I return or exchange healthcare equipment if it doesn't meet my needs?

No, we cannot.

Cn-Meditech

High Frequency Electrosurgical Unit Monopolar Bipolar Electrocautery Machine

$1,163.00

Model:CNME011117C

This electrosurgical unit delivers stable power output with low tissue thermal injury. Supporting hand/foot control and independent power adjustment, it is widely used in general surgery, gynecology, plastic surgery and veterinary operations for cutting, dissection and hemostasis.

Features:

The 416KHz (± 10%) high frequency current generated by this machine can perform
surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut, ; Monopolar coagulation: spray coagulation, soft
coagulation and standard bipolar six working modes.

*Full-function automatic power compensation.
*The high-frequency generator has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope, laparoscope and other endoscopes. 
*Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate. 
*Patient circuit bipolar electrode plate contact quality detection system. 
*Monopolar output can be controlled either by hand or foot, and monopolar/bipolar automatic output. 
*This machine has a power-off protection circuit, which can memorize the output set value of each function in real time. 
*Remote fault diagnosis. 
*Human voice alarm function
*Passed EMC test.

Rated output power:

*Pure cut:1w~350w(Max.400W,load 500 Ω);
A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasis. (No-focus precision cutting, 100% cutting.)

*Blend cut 1: 1W~250W(load 500 Ω);
Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.(Superficial focal gamma accurate cutting 80% cutting, 20% coagulation.)

*ENDU Cut: 99% (load 500 Ω);
The mode is used to automatically controlled cut system to reduce the complication rate of endoscopic sphincterotomy (EsT) and serum hyperamylasemia after EST compared to the conventional blended cut mode.

*Spray coagulation: 1W~80W(load 500 Ω);
Spray output is made for direct coagulation at the tissue with spark. Above spark does not give any cutting effect as its CREST FACTOR is high. (Massive coagulation)

*Desicate coagulation: 1W~120W(load 500 Ω);
Coagulation in which the active electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries it ensures pinpoint desiccation with less destruction of peripheral tissue.

*Standard bipolar coagulation: 1w~70w(load 100 Ω);
Bl-COAG- For highly precise control over coagulation process and privations of carbonization.

*Power consumption of the whole machine: ≤ 1100vA.(cut function 350W);

Normal operation:

*Ambient temperature range: 5℃~40℃;
*Relative humidity range: ≤ 80%;
*Atmospheric pressure range: 86.0~106.0kPa;
*Power supply: 220V±10%,50±1Hz; or110V±10%,60±1Hz
 *Working frequency: 416kHz;

Transportation and storage:

*Ambient temperature range:-40℃~55℃;
*Relative humidity range: ≤ 95%;
*Atmospheric pressure range: 50.0~106.0kPa.

View product